UK Building Compliance completed Air Pressure Testing and Sound Insulation Testing at this redevelopment of part of St Josephs Care Home in Manchester
-
The Sound Insulation Tests consisted of a mixture of Airborne Floor, Airborne Wall and Impact Floor tests
-
Airborne tests measure the difference in sound levels between the receiver room and neighbouring walls or floors
-
To pass these Airborne Floor tests, you must score 45db or hig her
-
If the sound output in the receiver room is 100db and the sound leakage being passed through into the neighbouring room is 40db, then the result would be 60 and therefore would be a pass
-
Impact Floor tests measure how effectively the Sound Insulation between floors cancels out sound
-
To pass these Impact Floor tests, you must score 62db or lower
-
If there is less than 62 decibels of sound leaking through into below floors then the test would be a pass
The process
-
After reviewing drawings, on site testing was ready to be completed. All calibrated equipment was setup in accordance to our strict procedures to ensure the most accurate result possible
-
We tested five flats in total, below are the Air Testing Results for two of the flats
THE RESULTS
- AIR TESTING RESULTS
≤ 3.0
Flat 52 Target
≤ 3.0
Flat 53 Target
2.82
Flat 52 Result
2.96
Flat 53 Result
PASS
PASS
- SOUND TESTING RESULTS
Airborne Floor Target
Airborne Floor Result
≥ 45
Flat 49 Lounge/Kitchen - Flat 25 Bedroom
Airborne Wall Target
≥ 45
Flat 49 Lounge/Kitchen - Flat 25 Bedroom
Impact Floor Target
≤ 62
Flat 49 Lounge/Kitchen - Flat 50 Bedroom
50
Flat 49 Lounge/Kitchen - Flat 25 Bedroom
Airborne Wall Result
51
Flat 49 Lounge/Kitchen - Flat 25 Bedroom
Impact Floor Result
58
Flat 49 Lounge/Kitchen - Flat 50 Bedroom
PASS
PASS
PASS
-
Complia nt
-
All of the Air Tightness Tests we conducted at this site passed
-